HLT_Mu37_Mu27_FromL1TkMuon

20.HLT_Mu37_Mu27_FromL1TkMuon

L1 seed: NOTHING

  • NOTE: This HLT path doesn't have any L1 seed!

HLT filters:

  • hltDoubleMuon7DZ1p0:
    select one (minN = cms.uint32(1)) L1 muon (GMTTkMuons) with MaxDz separation of 1, no \Delta R separation. This looks like a repetition of the L1 trigger seed, which already contains the \Delta Z requirement. In addition, both muons are required to be triggerType1 = cms.int32(-114), triggerType2 = cms.int32(-114)

    • NOTE: Should the triggerType1 be -83 from here?
  • hltL3fL1DoubleMu155fPreFiltered27:
    select two (minN = cms.uint32(2)) muons (hltPhase2L3Muons) with p_T>27 GeV, no \eta cut and at least 1 hit in the muon stations (minMuonStations = cms.int32(1))

  • hltL3fL1DoubleMu155fFiltered37:
    select one (minN = cms.uint32(2)) muon (hltPhase2L3Muons) with p_T>37 GeV, no \eta cut and at least 1 hit in the muon stations (minMuonStations = cms.int32(1))