HLT_Mu37_Mu27_FromL1TkMuon
20.HLT_Mu37_Mu27_FromL1TkMuon
L1 seed: NOTHING
- NOTE: This HLT path doesn't have any L1 seed!
HLT filters:
-
hltDoubleMuon7DZ1p0:
select one (minN = cms.uint32(1)) L1 muon (GMTTkMuons) withMaxDzseparation of 1, no \Delta R separation. This looks like a repetition of the L1 trigger seed, which already contains the \Delta Z requirement. In addition, both muons are required to betriggerType1 = cms.int32(-114), triggerType2 = cms.int32(-114)- NOTE: Should the
triggerType1be-83from here?
- NOTE: Should the
-
hltL3fL1DoubleMu155fPreFiltered27:
select two (minN = cms.uint32(2)) muons (hltPhase2L3Muons) with p_T>27 GeV, no \eta cut and at least 1 hit in the muon stations (minMuonStations = cms.int32(1)) -
hltL3fL1DoubleMu155fFiltered37:
select one (minN = cms.uint32(2)) muon (hltPhase2L3Muons) with p_T>37 GeV, no \eta cut and at least 1 hit in the muon stations (minMuonStations = cms.int32(1))